Standalone or Smart thermostat
A stylish mains-powered wall-mounted thermostat, or full Smart function control and data access through neoHub and the neoApp.
The Heatmiser neoStat – Pro embodies simplicity with its minimalist design and soft-glow digital display, providing essential temperature information for easy control. This thermostat introduces a new design language for Heatmiser products, combining minimalist aesthetics with smart control through the neoApp or smart home platforms like Amazon Alexa, Google Assistant, or Apple HomeKit.
Beyond its sleek design, the neoStat – Pro enhances your home’s climate control with advanced features. By leveraging reverse cooling technology, specifically with air or ground source heat pump systems, the neoStat – Pro supports comfort cooling for year-round temperature management. Its precise control is supported by floor and air temperature probes and a built-in humidity sensor.
For energy efficiency, it calculates the dew point and pauses cooling when needed to prevent condensation. This keeps your environment comfortable while conserving energy.
Providing subtle heating and comfort cooling control, the neoStat – Pro boosts comfort without sacrificing aesthetics or sustainability. It’s an ideal solution for modern, energy-conscious homes.
Smooth matt-white finish
Dimmable show-through display
Slim profile design
Dimensions | Control Panel H 85mm W 85mm D 12mm (PSU +25mm) |
Weight | 108 g |
Boxed Dimensions | H 70 mm W 112 mm D 97 mm |
Boxed Weight | 176 g |
What comes in the box | Thermostat, Manual, Domestic screws x2 |
Mounting type | Flush Mount |
Available Colours | Matt White |
Lock facility | Yes |
neoHub Compatibility | Yes |
neoHub Mini Compatibility | No |
Thermostat Mode | Yes |
Timer Mode | No |
Heating & Timer Mode | No |
Temperature Range | 05-35 °C, 41-95 °F |
Back Lit LCD Screen | Yes |
Non-Programmable Mode | Yes |
5/2 Day Programming Mode | Yes |
7 Day Programming Mode | Yes |
24 Hour Programming Mode | Yes |
Number of Heating Levels | 4 or 6 when connected |
Optimum Start | Yes |
Number of HW Times | None |
Holiday Function | Yes |
Temperature Hold Function | Yes |
Temperature Override | Yes |
Temperature Override Limit | Yes |
Frost Protection | Yes – Though neoHub & neoApp |
App Control | Yes |
°C / °F Option | Yes |
Remote Air Sensor Connection | Yes |
Built-in Air Sensor | Yes |
Floor Sensing Mode | Yes |
Floor Sensor Included | Yes |
Wireless Failsafe Function | No |
Max Switching Current | 3 amp |
Accuracy | +/- 1 °C |
Adjustable Switching Differential | 0.5 – 3°C |
Supply | 230 Volt AC |
Battery lifetime | n/a |
Output | 230 Volt AC |
Installed Dimensions | 85x85x12mm (L,H,D) |
Wireless Switching to UH8-RF/RF Switch | Yes |
RF Frequency | 2.4Ghz |
RF Range | Up to 40M |
Switching Differential | This function allows you to increase the switching differential of the thermostat. The default is 1°C which means that with a set temperature of 20°C, the thermostat will switch the heating on at 19°C and off at 20°C. With a 2°C differential, the heating will switch on at 18°C and off at 20°C. |
Frost Protect Temperature | This is the temperature maintained when the thermostat is in Frost Mode. The range is 05 – 17°C. The default is 12°C and is suitable for most applications. |
Output Delay | To prevent rapid switching, an output delay can be entered. This can be set from 00 – 15 minutes. The default is 00 which means there is no delay. |
Temperature Up/Down Limit | This function allows you to limit the use of the up and down temperature arrow keys. This limit is also applicable when the thermostat is locked and so allows you to give others limited control over the heating system. |
Sensor Selection | The neoStat Pro automatically detects and uses remote probe connections. Once connected, you may change sensor configuration via the neoApp to meet requirements. You can select between air temperature only, floor temperature, or both. When you enable both sensors, the floor sensor is used as a floor limiting sensor and is designed to prevent the floor from overheating. |
Dew Point | In cooling mode the thermostat will use the air, floor and humidity sensors to calculate the dew point temperature. Once the floor approaches dew point, the thermostat will stop cooling. |
Floor Temp Limit | This function is available when the thermostat is set to use air and floor sensing options. You can set a floor limiting temperature between 20-45°C (28°C is the default setting). Note: This unit MUST NOT be used to control electric underfloor heating. |
Cool Enable | Allows the thermostat to actively cool when the system is in cooling mode. |
Optimum Start | Optimum start will delay the start up of the heating system to the latest possible moment to avoid unnecessary heating and ensure the building is warm at the programmed time. The thermostat uses the rate of change information to calculate how long the heating needs to raise the building temperature 1°C (with a rate of change of 20, the thermostat has calculated the heating needs 20 minutes to raise the building temperature 1°C) and starts the heating accordingly |
Rate of Change | Number of minutes for 1°C temperature rise. The default setting is 20 minutes and can change on a daily basis. This setting cannot be changed and is for information only. |
Program Mode | Non-Programmable, Weekday/Weekend (5/2),7 Day Programming or 24 Hour. The thermostat offers three programming modes and the option of configuring it to work as a non-programmable thermostat.
Weekday/ Weekend – allows you to program 4 comfort levels for the weekday and 4 different comfort levels for the weekend. |
Temperature Format | This function allows you to select between °C and °F. |